Add reference architecture for production CM5 clusters
Document recommended storage layouts per node role: - Control planes: NVMe boot for fast etcd I/O - Postgres/storage: eMMC boot + NVMe data at /var/mnt/data - Compute workers: eMMC only, stateless Co-Authored-By: Claude Opus 4.6 <noreply@anthropic.com>
This commit is contained in:
parent
4e867e2055
commit
d260fe20ab
53
README.md
53
README.md
@ -167,6 +167,59 @@ talosctl -n <ip> dmesg | grep -i pcie
|
|||||||
# Look for "Gen 3" in the PCIe link speed output
|
# Look for "Gen 3" in the PCIe link speed output
|
||||||
```
|
```
|
||||||
|
|
||||||
|
## Reference architecture
|
||||||
|
|
||||||
|
Recommended storage layout for production Talos clusters on CM5 Compute Blade hardware. Each CM5 has a 32GB eMMC and an M.2 NVMe slot.
|
||||||
|
|
||||||
|
| Role | Boot disk | NVMe | EEPROM `BOOT_ORDER` | Rationale |
|
||||||
|
|------|-----------|------|---------------------|-----------|
|
||||||
|
| **Control plane** | NVMe | Talos OS | `0xf416` (NVMe first) | etcd lives on the STATE partition — NVMe gives ~800 MB/s sequential and ~50K random IOPS for fast consensus and snapshot I/O. |
|
||||||
|
| **Postgres / storage** | eMMC | Data (`/var/mnt/data`) | `0xf214` (eMMC first) | Talos OS on eMMC keeps `talosctl upgrade` away from the data drive. The full 1TB NVMe is dedicated to database storage via `machine.disks`. |
|
||||||
|
| **Compute workers** | eMMC | None | `0xf214` (eMMC first) | Stateless workloads — no local storage needed. eMMC is more than enough for Talos OS (~2.2GB used). |
|
||||||
|
|
||||||
|
### Storage configuration
|
||||||
|
|
||||||
|
**Control planes** — no extra config needed. Talos installs to the NVMe automatically when it's the boot disk.
|
||||||
|
|
||||||
|
**Postgres / storage nodes** — add `machine.disks` to mount the NVMe as a data volume:
|
||||||
|
|
||||||
|
```yaml
|
||||||
|
machine:
|
||||||
|
disks:
|
||||||
|
- device: /dev/nvme0n1
|
||||||
|
partitions:
|
||||||
|
- mountpoint: /var/mnt/data
|
||||||
|
```
|
||||||
|
|
||||||
|
Talos automatically partitions, formats (XFS), and mounts the NVMe on first boot. The data persists across `talosctl upgrade` since upgrades only touch the boot disk (eMMC).
|
||||||
|
|
||||||
|
**Compute workers** — no storage config needed.
|
||||||
|
|
||||||
|
### EEPROM setup
|
||||||
|
|
||||||
|
All CM5 modules require `PCIE_PROBE=1` for NVMe detection on Compute Blade (non-HAT+ carrier). Set via `rpiboot`:
|
||||||
|
|
||||||
|
```ini
|
||||||
|
# recovery/boot.conf
|
||||||
|
BOOT_ORDER=0xf416 # NVMe-first (control planes)
|
||||||
|
# or
|
||||||
|
BOOT_ORDER=0xf214 # eMMC-first (storage/compute workers)
|
||||||
|
PCIE_PROBE=1 # always required
|
||||||
|
```
|
||||||
|
|
||||||
|
### Overclock
|
||||||
|
|
||||||
|
All node types share the same overclock config (baked into the image via `config.txt.append`):
|
||||||
|
|
||||||
|
```ini
|
||||||
|
arm_freq=2600
|
||||||
|
over_voltage_delta=50000
|
||||||
|
arm_boost=1
|
||||||
|
dtparam=pciex1_gen=3
|
||||||
|
```
|
||||||
|
|
||||||
|
Verified stable at 44.6°C max under full CPU + memory + disk stress across 10 nodes with Compute Blade heatsinks.
|
||||||
|
|
||||||
## Building
|
## Building
|
||||||
|
|
||||||
For local builds, CI/CD setup, runner configuration, and project structure, see [TECHNICAL.md](TECHNICAL.md).
|
For local builds, CI/CD setup, runner configuration, and project structure, see [TECHNICAL.md](TECHNICAL.md).
|
||||||
|
|||||||
Loading…
Reference in New Issue